Item No. | Adherence to WHO vaccine cold chain management practice guideline (health workers practice) | Frequency (percentage) | |
---|---|---|---|
Yes (%) | No (%) | ||
1 | The refrigerator is dedicated for storage of cold chain pharmaceuticals (n=26) | 10 (39.5%) | 16 (61.5%) |
2 | The refrigerator have sufficient storage capacity (n=26) | 23 (88.5%) | 3 (11.5%) |
3 | Vaccines are properly arranged in refrigerator (n=26) | 9 (34.6%) | 17 (65.4%) |
4 | Vaccine management following EEFO principle (n=28) | 12 (42.9%) | 16 (57.1%) |
5 | The expired vaccines are not present in refrigerator (n=26) | 19 (73.1%) | 7 (26.9%) |
6 | The frozen vaccines are not present in refrigerator (n=26) | 20 (76.9%) | 6 (22.1%) |
7 | Refrigerator temperature maintained between 2-80C (n=26) | 23 (88.5%) | 3 (11.5%) |
8 | Functional thermometer present in the refrigerator (n=26) | 8 (30.8%) | 18 (69.2%) |
9 | The refrigerator T0 recorded twice daily as reflected by temperature registration sheet on the door of refrigerator (n=26) | 9 (34.6%) | 17 (65.4%) |
10 | The refrigerator is protected from direct sun light to aid good refrigerator care (n=26) | 12 (46.2%) | 16 (57.1%) |
11 | All vaccine receipt and transactions is recorded (n=28) | 9 (32.1%) | 19 (67.9%) |
12 | The VVM status of vaccine recorded for each vaccine in vaccine status registration book (n=28) | 3 (10.7%) | 25 (89.2%) |
13 | Vaccine LMIS (Logistic management information system) reporting and requisition form done in the last month (n=28) | 7 (25%) | 21 (75%) |
14 | Presence of standby power supply beside the main sources (n=28) | 2 (7.1%) | 26 (92.9%) |
15 | Cold chain pharmaceutical are stored on doors of the refrigerator shelf (n=26) | 15 (57.7%) | 11 (42.3%) |