Skip to main content

Table 3 Continuous episodes of temperature excursion below 0 °C in cold chain devices

From: Temperature integrity and exposure of vaccines to suboptimal temperatures in cold chain devices at different levels in three states of India

  

Total observation perioda

Exposure to temperature < 0 °C

Total durationa (hours)

Total continuous episodes durationa (hours)

Duration of continuous episodesb

≤1 h

> 1–9 h

≥10 h

State and Division

Bihar

4107.5

540

28.9

12.7

14

2.2

Gujarat

1395

5.75

0.7

0.2

0.5

0

Kerala

860.5

0

0

0

0

0

Total

6363

545.7

29.7

13

14.5

2.2

District

Bihar

5163.7

666.7

5.9

0.7

2.7

2.5

Gujarat

3228.7

4.5

0.7

0

0.7

0

Kerala

1914.5

19

1

0

1

0

Total

10,307

690.2

7.7

0.7

4.5

2.5

Sub-district

Bihar

23,728.2

4663.2

41.9

5.2

19

17.7

Gujarat

12,115.2

2415.7

62.9

29.2

26.2

7.5

Kerala

6526.2

421.2

14.9

3

10.2

1.7

Total

42,369.7

7500.2

120

37.5

55.5

27

WICs

Bihar

3483.2

303.2

22.2

12.2

8

2

Gujarat

1036.7

5.75

0.7

0.2

0.5

0

Kerala

718.5

0

0

0

0

0

Total

5238.5

309

23

12.5

8.5

2

ILRs

Bihar

28,452.2

5563.2

53.7

5.7

27.5

20.5

Gujarat

15,702.2

2420.2

63.7

29.2

27

7.5

Kerala

8582.7

440.2

16.4

3

11.7

1.7

Total

52,737.2

8423.7

133.4

38

65.7

29.7

Other devicesc

Bihar

1064

3.5

0.9

0.7

0.2

0

Total

1064

3.5

0.9

0.7

0.2

0

Pooled all levels

Bihar

32,999.5

5870

76.9

18.7

35.7

22.5

Gujarat

16,739

2426

64.5

29.5

27.5

7.5

Kerala

9301.2

440.2

16.4

3

11.7

1.7

Total

59,039.7

8736.2

157.7

51.5

74.5

31.7

  1. WIC Walk-in cooler, ILR Ice lined refrigerator
  2. a Duration in hours
  3. b A continuous episode below 0 °C was counted when readings were continuously below 0 °C for at least 45 min or more
  4. c Other devices (domestic refrigerator and cold boxes) were used for vaccine storage in Bihar only at the time of the study